Warning
Caution
1. Place a battery in a pan of water to prevent it from overheating.
2. The water level should come up about halfway on the battery.
3. Remove the battery plugs while charging the battery.
4. Keep water off the top of the battery.
Caution
5. Connect a battery charger to the battery.
6. Adjust the charging current as follows.


Battery inspection
Generator removal/installationMazda 6 Service Manual: Heated oxygen sensor (ho2s) inspection
HO2S Voltage Inspection
Note
Perform the following inspection only when directed.
1. Warm up the engine and run it at idle.
2. Disconnect the HO2S connector.
3. Connect the voltmeter test leads to the following HO2S terminals:
HO2S (front and rear)
- (+) leadterminal A
- (-) le ...
Mazda 6 Service Manual: Inboard combination light removal/installation
1. Disconnect the negative battery cable.
2. Remove the trunk lid trim (liftgate lower trim). (See TRUNK LID TRIM
REMOVAL/INSTALLATION) (See LIFTGATE LOWER TRIM REMOVAL/INSTALLATION)
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
Inboard Combinat ...