Mazda 6 manuals

Mazda 6 Service Manual: Dtc p0123



Diagnostic procedure



Dtc p0122
Diagnostic procedure ...

Dtc p0125
Diagnostic procedure ...

Other materials:

Mazda 6 Service Manual: Running light unit inspection
1. Connect the connector to the running light unit. 2. Connect the negative battery cable. 3. Measure the voltage at the running light unit using voltmeter. When inspecting terminal D, H or P for continuity, disconnect the running light unit connector. 4. If the value are not as specif ...

Mazda 6 Service Manual: Oil control valve (ocv) inspection
L3 Coil Resistance Inspection 1. Disconnect the negative battery cable. 2. Disconnect the oil control valve connector. 3. Measure the resistance between terminals A and B using an ohmmeter. If not as specified, replace the oil control valve. Specification 6.9-7.9 ohms 4. Connect ...