Diagnostic procedure


* : If there is gas leakage, air enters into the A/C system. The desiccant within the receiver/drier absorbs the moisture from the air and becomes saturated. If the A/C system is used in this condition, the inside of the A/C compressor will begin to rust due to this moisture, which may cause lock up or noise to occur. Therefore, replacement of the receiver/drier is necessary.
No.8 no cool air
Technical dataMazda 6 Service Manual: Running light unit inspection
1. Connect the connector to the running light unit.
2. Connect the negative battery cable.
3. Measure the voltage at the running light unit using voltmeter.
When inspecting terminal D, H or P for continuity, disconnect the running light unit connector.
4. If the value are not as specif ...
Mazda 6 Service Manual: Variable valve timing actuator removal/installation
L3
Caution
Variable valve timing actuator can not be disassembled because it
is a precision unit.
Note
Variable valve timing actuator camshaft sprocket is integrated
with the variable valve timing actuator and cannot be disassembled.
1. Follow the timing chain removal/installati ...