Fuel Leakage Inspection
Warning
Caution
1. Short the check connector terminal F/P to body GND using a jumper wire.

2. Turn the ignition switch to ON position to operate the fuel pump.
3. Pressurize the system in this way for at least 5 minutes
to be sure of no leakage.
4. After repair, assemble the system and repeat Steps 1 to 3.
Before repair procedure
Fuel tank removal/installationMazda 6 Service Manual: Battery inspection
Battery
Inspect the battery in the following procedure.
Test load chart
Battery positive voltage with load
Back-up Current
1. Verify that the engine switch is at OFF and that the key has been removed.
2. Disconnect the negative battery cable.
3. Measure the back-up current between the n ...
Mazda 6 Service Manual: Variable air duct (vad) shutter valve inspection (l3)
1. Remove the air cleaner case. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
2. Disconnect the vacuum hose from the VAD shutter valve actuator.
3. Connect a vacuum pump to the VAD shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
If the rod dose not move, replace the a ...