Mazda 6 manuals

Mazda 6 Service Manual: No.3 amount of air blown from vents does not change

Mazda 6 Service Manual / Heater and air conditioner systems / Troubleshooting / No.3 amount of air blown from vents does not change

Manual Air Conditioner


Diagnostic procedure



No.2 amount of air blown from vents does not change
Full-auto Air Conditioner When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor c ...

No.4 air intake mode does not change
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause ...

Other materials:

Mazda 6 Service Manual: Generator inspection
Generator Warning Light 1. Verify that the battery is fully charged. Charge if necessary. 2. Verify that the drive belt deflection/tension is correct. (See DRIVE BELT INSPECTION.) If not as specified, replace the drive belt. 3. Turn the ignition switch to ON and verify that the gene ...

Mazda 6 Service Manual: Oil control valve (ocv) inspection
L3 Coil Resistance Inspection 1. Disconnect the negative battery cable. 2. Disconnect the oil control valve connector. 3. Measure the resistance between terminals A and B using an ohmmeter. If not as specified, replace the oil control valve. Specification 6.9-7.9 ohms 4. Connect ...