Inspection during removal, disassembly
Cleaning of partsMazda 6 Service Manual: Liftgate adjustment
1. Measure the gap and height between the liftgate and the body.
2. If not as specified, loosen the liftgate hinge installation bolts or the
liftgate striker installation screws, and reposition the liftgate.
Clearance
a: 3.0-7.0 mm {0.12-0.28 in}
b: -1.0-3.4 mm {-0.04-013 in}
c: 2.8-5.2 mm ...
Mazda 6 Service Manual: Purge solenoid valve inspection
Airflow Inspection
Note
Perform the following test only when directed.
1. Disconnect the negative battery cable.
2. Remove the purge solenoid valve. (See PURGE SOLENOID VALVE
REMOVAL/INSTALLATION.)
3. Inspect airflow between the ports under the following conditions.
If not as specifi ...