Diagnostic procedure


Dtc p0711
Dtc p0713Mazda 6 Service Manual: Abs (abs/tcs) hu/cm inspection
1. Disconnect the negative battery cable.
2. Connect the SST between the ABS (ABS/TCS) HU/CM and harness
connector with the ignition switch off.
3. Attach the tester leads to the SST and inspect voltage referring
the table below.
Terminal Voltage Table (Reference)
(Engine is idling, and co ...
Mazda 6 Service Manual: Disconnection of the negative battery cable
Before beginning any work, turn the ignition switch to LOCK position,
then disconnect the negative battery cable and wait for more than 1 minute
to allow the backup power supply of the SAS unit to deplete its stored
power. Disconnecting the battery cable will delete the memories of the
...