1. Install the SST
(gas charging set).
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the SST
(manifold gauge) and continuity between the terminals of the refrigerant pressure switch.
Triple-pressure Type



Dual-pressure Type


Refrigerant pressure switch removal/installation
Climate control unit removalMazda 6 Service Manual: Cooling (With air conditioner)
1. Set the mode selector dial to the
position.
2. Set the temperature control dial to the cold position.
3. Set the fan control dial to the desired speed.
4. Turn on the air conditioner by pressing the A/C switch.
5. After cooling begins, adjust the fan control dial and temperature control
d ...
Mazda 6 Service Manual: Rear window glass removal
1. For the 4SD, remove the following parts:
(1) Remove the headliner.
(2) Remove the rear package trim.
2. For the 5HB, remove the following parts.
(1) Remove the rear wiper arm and blade.
(2) Remove the liftgate lower trim.
3. Apply protective tape along the edge of the body to pr ...