Connect battery positive voltage to terminal A and ground to terminal B of the blower motor and verify its operation.

Blower motor removal/installation
Resistor removal/installationMazda 6 Service Manual: Radiator
RADIATOR REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Drain the engine coolant. (See ENGINE COOLANT REPLACEMENT.)
3. Remove the cooling fan. (See COOLING FAN REMOVAL/INSTALLATION.)
4. Remove the oil hose. (ATX)
5. Remove in the order indicated in the table.
6. Install in t ...
Mazda 6 Service Manual: Egr valve inspection
Operation Test
Carry out the EGR Control Inspection. (See EGR Control System
Inspection.
If not as specified, perform the further inspection for the EGR valve.
Resistance Inspection
Note
Perform the following test only when directed.
1. Disconnect the negative battery cable.