Diagnostic procedure
Mazda 6 Service Manual: Pcv valve inspection
1. Disconnect the negative battery cable.
2. Remove the intake maniforld.(see INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
3. Remove the PCV valve.
4. Blow through the valve and verify that air flows as specified.
If not as specified, replace the PCV valve.
Specification
...
Mazda 6 Service Manual: Transaxle range (tr) switch inspection
Operating Inspection
1. Verify that the starter operates only when the ignition switch is at the
START position with the selector lever in P or N position.
If not as specified, adjust the TR switch.
2. Verify that the back-up lights illuminate when shifted to R position with
the ignition ...