1. Install the SST
(gas charging set).
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the SST
(manifold gauge) and continuity between the terminals of the refrigerant pressure switch.
Triple-pressure Type



Dual-pressure Type


Refrigerant pressure switch removal/installation
Climate control unit removalMazda 6 Service Manual: Cigarette lighter removal/installation
1. Disconnect the negative battery cable.
2. Remove in the order indicated in the table.
3. Install in the reverse order of removal.
Socket Removal Note
1. Insert a tape-wrapped screwdriver into the socket hole, then press against
the ring protrusion to lift the socket toward you.
2. As ...
Mazda 6 Service Manual: Transaxle range (tr) switch removal/installation
1. Disconnect the negative battery cable.
2. Remove the air cleaner component. (See INTAKE-AIR SYSTEM
REMOVAL/INSTALLATION.)
Caution
Water or foreign objects entering the connector can cause a poor
connection or corrosion. Be sure not to drop water or foreign objects on the
connector w ...