1. Connect battery positive voltage to terminal D or F and ground to terminal F or D of the air mix actuator.
2. Verify that the air mix actuator operates as shown below.
e



3. Verify that the resistance between the terminals of the air mix actuator are as shown in the graph.

Air mix actuator removal/installation
Airflow mode actuator removal/installationMazda 6 Service Manual: Combine sensor inspection
Caution
Be careful and do not allow the lateral-G sensor to fall. If by
chance it is subjected to strong impact, replace it.
1. Connect the connector.
2. Turn ignition switch on, verify the voltage between terminals B and E
under the following conditions.
If not within the specifi ...
Mazda 6 Service Manual: Purge solenoid valve removal/installation
1. Disconnect the negative battery cable.
2. Remove in the order indicated in the table.
3. Install in the reverse order of removal.
Vacuum Hose Installation Note
Attach the vacuum hose onto the purge solenoid valve until it contacts the
stopper.
Evaporative Hose Installation Note
Attach ...