Diagnostic procedure


* : If there is gas leakage, air enters into the A/C system. The desiccant within the receiver/drier absorbs the moisture from the air and becomes saturated. If the A/C system is used in this condition, the inside of the A/C compressor will begin to rust due to this moisture, which may cause lock up or noise to occur. Therefore, replacement of the receiver/drier is necessary.
No.8 no cool air
Technical dataMazda 6 Service Manual: Climate control unit disassembly/assembly
1. Disassemble in the order indicated in the table.
2. Assemble in the reverse order of disassembly.
Wire Disassembly Note
Disassemble the wires in the shown in the figure.
Wire Assembly Note
Assemble the wires to the position as shown in the figure.
...
Mazda 6 Service Manual: Variable air duct (vad) control solenoid valve inspection (l3)
1. Remove the VAD control solenoid valve. (See INTAKE-AIR SYSTEM
REMOVAL/INSTALLATION.)
2. Inspect airflow between the ports under the following conditions.
If not as specified, replace the VAD control solenoid valve.
If as specified, carry out the Circuit Open/Short Inspection.
Circ ...