Diagnostic procedure


* : If there is gas leakage, air enters into the A/C system. The desiccant within the receiver/drier absorbs the moisture from the air and becomes saturated. If the A/C system is used in this condition, the inside of the A/C compressor will begin to rust due to this moisture, which may cause lock up or noise to occur. Therefore, replacement of the receiver/drier is necessary.
No.8 no cool air
Technical dataMazda 6 Service Manual: Climate control unit wire adjustment
Air Mix Wire
1. Set the temperature control dial at max cold.
2. Set the air mix link to max cold in the direction shown by the arrow and
insert a screwdriver at the set hole.
3. Connect the air mix wire to air mix link.
4. Clamp the air mix wire to wire clamp.
5. Verify that the temperatur ...
Mazda 6 Service Manual: Dtc clearing procedure
1. Start the on-board diagnostic test mode.
2. First press the POWER button, then simultaneously press AUDIO CONT button
for 2 seconds or more.
Caution
Before clearing the DTCs, be sure to enter all of them displayed
in the on-board diagnostic test mode in the Audio Repair Order Form. ...