Diagnostic procedure


* : If there is gas leakage, air enters into the A/C system. The desiccant within the receiver/drier absorbs the moisture from the air and becomes saturated. If the A/C system is used in this condition, the inside of the A/C compressor will begin to rust due to this moisture, which may cause lock up or noise to occur. Therefore, replacement of the receiver/drier is necessary.
No.8 no cool air
Technical dataMazda 6 Service Manual: Snow Tires
Use snow tires on all four wheels
Do not go faster than 120 km/h (75 mph) while driving with snow tires. Inflate
snow tires 30 kPa (0.3 kgf/cm2, 4.3 psi) more than recommended on the tire pressure
label (driver's door frame), but never more than the maximum cold-tire pressure
shown on the tir ...
Mazda 6 Service Manual: Jam-safe Moonroof
If a person's hands, head or an object blocks the moonroof while it is closing,
the moonroof will stop and move in the reverse direction.
WARNING
Make sure nothing blocks the moonroof just before it reaches the fully closed
position: Blocking the moonroof just before it reaches the closed posi ...