Diagnostic procedure


* : If there is gas leakage, air enters into the A/C system. The desiccant within the receiver/drier absorbs the moisture from the air and becomes saturated. If the A/C system is used in this condition, the inside of the A/C compressor will begin to rust due to this moisture, which may cause lock up or noise to occur. Therefore, replacement of the receiver/drier is necessary.
No.8 no cool air
Technical dataMazda 6 Service Manual: Center panel module disassembly/assembly
Caution
Before disassembling the center panel module, spread a cloth on the floor to
put the disassembled parts on. This protects the surface of the panel from
scratches or dirt.
1. Remove the center panel module. (See CENTER PANEL MODULE
REMOVAL/INSTALLATION.)
2. Remove in the order i ...
Mazda 6 Service Manual: Airflow mode actuator inspection
1. Connect battery positive voltage to terminal D or F and ground to terminal
F or D of the airflow mode actuator.
2. Verify that the airflow mode actuator operates as shown below.
If not as specified, replace the airflow mode actuator.
3. Verify that the resistance between the ter ...