Erasing Programmed HomeLink Buttons
Brake SystemMazda 6 Owners Manual: Running light unit inspection
1. Connect the connector to the running light unit.
2. Connect the negative battery cable.
3. Measure the voltage at the running light unit using voltmeter.
When inspecting terminal D, H or P for continuity, disconnect the running light unit connector.
4. If the value are not as specif ...
Mazda 6 Owners Manual: Clock spring inspection
1. Remove the clock spring.
2. Inspect for continuity between the clock spring terminals using an
ohmmeter.
If not as specified, replace the clock spring.
Note
When the vehicle-side connector of clock spring is disconnected,
the terminals 1A,1B, 1C and 1D are shorted to prevent ...