Caution
The high-tension leads must be reinstalled to their original position.Incorrect installation can damage the leads and cause power loss, and negatively affect the electronic components.
1. Disconnect the negative battery cable.
2. Remove the plug hole plate.
3. Remove the high-tension lead.
4. Install the high-tension lead.
Mazda 6 Service Manual: Combine sensor inspection
Caution
Be careful and do not allow the lateral-G sensor to fall. If by
chance it is subjected to strong impact, replace it.
1. Connect the connector.
2. Turn ignition switch on, verify the voltage between terminals B and E
under the following conditions.
If not within the specifi ...
Mazda 6 Service Manual: Variable air duct (vad) shutter valve inspection (l3)
1. Remove the air cleaner case. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
2. Disconnect the vacuum hose from the VAD shutter valve actuator.
3. Connect a vacuum pump to the VAD shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
If the rod dose not move, replace the a ...