1. Disconnect the negative battery cable.
2. Remove in the order indicated in the table.


3. Install in the reverse order of removal.
Vacuum Hose Installation Note
Attach the vacuum hose onto the purge solenoid valve until it contacts the stopper.
Evaporative Hose Installation Note
Attach the evaporative hose onto the purge solenoid valve until it contacts the stopper.
Evaporative gas check valve (one-way) inspection (l.h.d.)
Purge solenoid valve inspectionMazda 6 Service Manual: Door lock timer unit inspection
1. Measure the voltage at the door lock timer unit terminals (other than
terminal 1E and 2W) as indicated below.
If not as specified, inspect the parts listed under Action.
2. Disconnect the negative battery cable.
3. Disconnect the door lock timer unit connector and inspect for continuity ...
Mazda 6 Service Manual: Refrigerant pressure switch inspection
1. Install the SST (gas charging set).
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the SST (manifold gauge)
and continuity between the terminals of the refrigerant pressure switch.
If not as specified, replace the refrigerant pressure ...