Constant Monitoring
KeysMazda 6 Owners Manual: Ignition coil inspection
Primary Coil Winding
1. Remove the ignition coil.
2. Measure the resistance between the following lead holes using an ohmmeter.
A and B, B and C
- If not specified, replace the ignition coil.
Specification
0.49-0.57 ohms [20°C {68°F}]
Secondary Coil Winding
1. Remove the igni ...
Mazda 6 Owners Manual: Evaporator temperature sensor inspection
1. Turn the AUTO switch on.
2. Set the temperature control at MAX COLD (Turn the left).
3. Turn the A/C switch.
4. Set the RECIRCULATE mode.
5. Close all doors and windows.
6. Wait for 5 minutes.
7. Remove the glove compartment.
8. Disconnect the evaporator temperature sensor.
9. Measure t ...